The most powerful device on the market
- Balancing
- Thermography
- Camera
- Ultrasound
- Bump test for identifying natural frequency
- ODS
- MCSA
And much more…
Technical specifications
NUMBER OF MEASURING CHANNELS
4 x AC, ICP® supply on/off
4 x DC for process values such as (pressure, temperature, kW, etc.)
1 x TACHO for measuring revolutions / external triggers
RANGE
AC +/- 12 V peak-peak
DC +/- 24V
FREQUENCY RANGE (-3 dB)
Maximum range: 0.35 Hz – 90 kHz (1 Ch, 194 kHz sampling)
Maximum range: 0.35 Hz – 25 kHz (4 Ch, 64 kHz sampling)
Minimum range: 0.35 Hz – 25 Hz (4 Ch, 64 Hz sampling)
SAMPLING
Fully synchronised on all 4 channels
FFT SOLUTION
Min. 100 lines
Max. 3,276,800 lines
MEASUREMENT MODES
Analyser – analytical measurements
Data collector – route measurements
Balancers – 1 and 2 plane on-site balancing
Run up – run up and coast down measurements
Recorder – raw signal recording for later post analysis
FASIT – expert system for automatic fault detection
Octave analyzer – hearable sound measurements
Bump test – measurement of natural frequencies
ADS – Animated Deflection Shapes (Operating deflection shapes)
Ultrasound – measurement of ultrasound in the 30–50 kHz range
Camera
Infrared Camera
Gallery
DISPLAY
1125 x 800 pixels
THERMOGRAPHY (optional)
384 x 288 pixels
-10°C to 250°C temperature range
50 mK NETD sensitivity
MEMORY
64 GB, max. 16 GB for a route
DATA PROCESSING
Real-time FFT
DEMOD – ENVELOPE analysis
ACMT – low speed bearing analysis
Order analysis
User band pass analysis
RPM measurement
DC measurement
Orbit measurement
RECORDING OF RAW TIME SIGNAL
64 kHz sampling frequency
4 Ch memory with 3 GB/hour
4 Ch total recording time – 20 hours
TRIGGER
Manual, External, Signal level, Time Speed change, Time interval
POWER
Battery with 8-hour capacity, AC 230 V
WEIGHT
2000 g
DIMENSIONS
295 x 230 x 49 cm